Wiring to the Control Panel

Run the wiring connections from the module to the data bus terminals on the compatible control panel. Connect the Ethernet cable to the Ethernet port on the module.

Callout – Description
1 – SD12 control panel. ForSDI control panels, wire R, Y, G, B to the SDI bus
2 – Module
3 – To the Ethernet network
4 – Terminal strip wiring
5 – Interconnect cable (P/N: F01U079745) (included)

Programming Control Panel

Enables External Network

ItemLocationOptionDefault
External Network Module 100810 = Not Used
1 = Use, do not configure
2 = Use and configure
3 = Used, B4xx-M
0
Module 1 Cloud Connection44560 = Disable
4 = Enable
0

Program 0081 to 3

Program 4456 to 4

Setup Mobile Apps

  • Download BSC+ from Apple Store / Play Store
  • Register a new user account. Make sure you need to activate your account from the email account.
  • Add a new panel by scan the QR code.
  • Select this panel and use your Code Pad password to Connect.